John Deere Mobile Weather

Double tap to zoom

 

Features

Manage efficacy and potential drift of chemical applications

Monitor weather conditions to optimize effectiveness of chemical application.
#

Utilize the custom alerts and weather information to make educated decisions about when to spray.  Monitoring temperature, wind speed, wind direction, Delta T, and relative humidity on the go allows operators to quickly and easily understand if the weather conditions are favorable or not for product application. Built-in alerts make it easy for operators to set operational parameters to know when unfavorable weather conditions are present. Having weather information in the cab allows operators to increase product efficacy and decrease the risk of chemical drift. 

Red background indicates customizable alert has been exceeded

Delta T is a calculation that indicates the acceptable conditions to apply product; the value indicates if the product applied will evaporate prior to being absorbed by the plant. Delta T is a calculated by subtracting the wet bulb temperature from the dry bulb temperature. When applying, Delta T should be between 2⁰C (4⁰F) and 8⁰C (14⁰F), and not greater than 10⁰C (18⁰F). A higher Delta T value results in a faster evaporation rate and shorter droplet lifetime. Applicators can utilize the customizable alerts to notify the operator when Delta T is too high and product application is not favorable in order to ensure maximum product effectiveness.

Capture instantaneous weather information

Capture in-field weather information for on the go decision making. Accurate information is critical when making decisions surrounding chemical application. Why not use weather information that is specific to the operator and area being covered? John Deere Mobile Weather displays five critical values needed for when determining the effectiveness of chemical application.

  • Wind speed (true)
  • Wind direction
  • Delta T
  • Temperature
  • Relative humidity

True wind speed is wind experienced by a stationary object. Apparent wind speed is the total wind experienced without compensation for machine speed and direction.

John Deere Mobile Weather utilizes a third-party weather sensor that connects to the John Deere Application Controller 1120. Weather data is collected and distributed to the GreenStar™ 3 (GS3) 2630 Display for viewing and documentation. John Deere Mobile Weather activation is required to utilize the Application Controller 1120 in order to monitor weather information and is included with the purchase of the product.

Producers running a GS3 2630 are capable of documenting weather data, all other compatible GreenStar 2 (GS2) Displays will only be able to display the weather data without the ability to record. Once the weather information is collected in the GS3 2630, it can then be transferred to Apex™ software system for further analysis and record keeping. Apex has the ability to map air temperature, wind speed, and Delta T, while wind direction and humidity is available to be seen within the summary information.

Specifications

System specifications:

John Deere Mobile Weather provides system accuracy within +/- 6.4 km/h (+/- 4 mph) up to a 64.3 km/h (40 mph) apparent wind. Apparent wind speed is the total wind experienced without compensation for machine speed and direction. Operating with a headwind and tailwind increases vehicle turbulence, negatively impacting wind speed accuracy. For optimal performance Mobile Weather is recommended to be utilized in vehicle operation speeds less than 32 km/h (20 mph). John Deere Mobile Weather is not recommended for use in dry-box applications.

 

NOTE: When the wind speed is less than 7.4 km/h (4.6 mph) and/or air temperature is below 0C (32F), wind, temperature, and relative humidity readings will be less accurate.

 

NOTE: Specifications for new sensor. System performance may vary based upon application.

Measurements:
  • Measurement time: 10 minutes
  • Power: 2.5 VDC at 2 mA, to 5 VDC at 7 mA
  • Output: 320-1000 mV at 3-V excitation
  • Operating temperature range: -40-55⁰C (-40-131⁰F)
  • Air temperature range: -40-55⁰C (-40-131⁰F)
  • Air temperature resolution: 0.1⁰C (-0.1⁰F)
  • Air temperature accuracy: ±1⁰C (±1.8⁰F), wind greater than 7.4 km/h (4.6 mph)
  • Relative humidity range: 10-95 percent relative humidity
  • Relative humidity accuracy: ±4 percent relative humidity
  • Wind speed range: 0-144 km/h (0-92 mph)
  • Wind speed accuracy, Low wind speed: 0-18.5 km/h (0-11.5 mph), root-mean-square (RMS) error of 1.8 km/h (1.1 mph) + 10 percent of reading
  • Wind speed accuracy, High wind speed: 18.5-144.5 km/h (11.5-90 mph), RMS error of 3.7 km/h (2.3 mph) or 5 percent RMS, whichever is greater
  • Wind direction range: 0 degrees to 360 degrees
  • Wind direction resolution: ±0.1 degrees
  • Wind direction accuracy, low wind speed: 7.4-18.5 km/h (4.6-11.5 mph), 5 degrees RMS, typical
  • Wind direction accuracy, high wind speed: Greater than 18.5 km/h (greater than 11.5 mph), 2 degrees RMS, typical

NOTE: When the wind speed is less than 7.4 km/h (4.6 mph) and/or air temperature is below 0C (32⁰ F), wind, temperature, and relative humidity readings will be less accurate.

 

RMS error is a measure of the differences between values predicted by a model and the values actually observed.

Dimensions, sensor body

  • Diameter, top: 72 mm (2.83 in.)
  • Diameter, nut assembly, connection with sensor body: 45 mm (1.77 in.)
  • Length, total: 131 mm (5.16 in.)
  • Length, sensor body: 90 mm (3.54 in.)